Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
2.
JMIR Form Res ; 8: e50035, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38691395

RESUMEN

BACKGROUND: Wrist-worn inertial sensors are used in digital health for evaluating mobility in real-world environments. Preceding the estimation of spatiotemporal gait parameters within long-term recordings, gait detection is an important step to identify regions of interest where gait occurs, which requires robust algorithms due to the complexity of arm movements. While algorithms exist for other sensor positions, a comparative validation of algorithms applied to the wrist position on real-world data sets across different disease populations is missing. Furthermore, gait detection performance differences between the wrist and lower back position have not yet been explored but could yield valuable information regarding sensor position choice in clinical studies. OBJECTIVE: The aim of this study was to validate gait sequence (GS) detection algorithms developed for the wrist position against reference data acquired in a real-world context. In addition, this study aimed to compare the performance of algorithms applied to the wrist position to those applied to lower back-worn inertial sensors. METHODS: Participants with Parkinson disease, multiple sclerosis, proximal femoral fracture (hip fracture recovery), chronic obstructive pulmonary disease, and congestive heart failure and healthy older adults (N=83) were monitored for 2.5 hours in the real-world using inertial sensors on the wrist, lower back, and feet including pressure insoles and infrared distance sensors as reference. In total, 10 algorithms for wrist-based gait detection were validated against a multisensor reference system and compared to gait detection performance using lower back-worn inertial sensors. RESULTS: The best-performing GS detection algorithm for the wrist showed a mean (per disease group) sensitivity ranging between 0.55 (SD 0.29) and 0.81 (SD 0.09) and a mean (per disease group) specificity ranging between 0.95 (SD 0.06) and 0.98 (SD 0.02). The mean relative absolute error of estimated walking time ranged between 8.9% (SD 7.1%) and 32.7% (SD 19.2%) per disease group for this algorithm as compared to the reference system. Gait detection performance from the best algorithm applied to the wrist inertial sensors was lower than for the best algorithms applied to the lower back, which yielded mean sensitivity between 0.71 (SD 0.12) and 0.91 (SD 0.04), mean specificity between 0.96 (SD 0.03) and 0.99 (SD 0.01), and a mean relative absolute error of estimated walking time between 6.3% (SD 5.4%) and 23.5% (SD 13%). Performance was lower in disease groups with major gait impairments (eg, patients recovering from hip fracture) and for patients using bilateral walking aids. CONCLUSIONS: Algorithms applied to the wrist position can detect GSs with high performance in real-world environments. Those periods of interest in real-world recordings can facilitate gait parameter extraction and allow the quantification of gait duration distribution in everyday life. Our findings allow taking informed decisions on alternative positions for gait recording in clinical studies and public health. TRIAL REGISTRATION: ISRCTN Registry 12246987; https://www.isrctn.com/ISRCTN12246987. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2021-050785.

3.
PLoS One ; 19(4): e0299099, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38564618

RESUMEN

Individual muscle segmentation is the process of partitioning medical images into regions representing each muscle. It can be used to isolate spatially structured quantitative muscle characteristics, such as volume, geometry, and the level of fat infiltration. These features are pivotal to measuring the state of muscle functional health and in tracking the response of the body to musculoskeletal and neuromusculoskeletal disorders. The gold standard approach to perform muscle segmentation requires manual processing of large numbers of images and is associated with significant operator repeatability issues and high time requirements. Deep learning-based techniques have been recently suggested to be capable of automating the process, which would catalyse research into the effects of musculoskeletal disorders on the muscular system. In this study, three convolutional neural networks were explored in their capacity to automatically segment twenty-three lower limb muscles from the hips, thigh, and calves from magnetic resonance images. The three neural networks (UNet, Attention UNet, and a novel Spatial Channel UNet) were trained independently with augmented images to segment 6 subjects and were able to segment the muscles with an average Relative Volume Error (RVE) between -8.6% and 2.9%, average Dice Similarity Coefficient (DSC) between 0.70 and 0.84, and average Hausdorff Distance (HD) between 12.2 and 46.5 mm, with performance dependent on both the subject and the network used. The trained convolutional neural networks designed, and data used in this study are openly available for use, either through re-training for other medical images, or application to automatically segment new T1-weighted lower limb magnetic resonance images captured with similar acquisition parameters.


Asunto(s)
Aprendizaje Profundo , Humanos , Femenino , Animales , Bovinos , Procesamiento de Imagen Asistido por Computador/métodos , Posmenopausia , Muslo/diagnóstico por imagen , Músculos , Imagen por Resonancia Magnética/métodos
4.
Sci Rep ; 14(1): 1754, 2024 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-38243008

RESUMEN

This study aimed to validate a wearable device's walking speed estimation pipeline, considering complexity, speed, and walking bout duration. The goal was to provide recommendations on the use of wearable devices for real-world mobility analysis. Participants with Parkinson's Disease, Multiple Sclerosis, Proximal Femoral Fracture, Chronic Obstructive Pulmonary Disease, Congestive Heart Failure, and healthy older adults (n = 97) were monitored in the laboratory and the real-world (2.5 h), using a lower back wearable device. Two walking speed estimation pipelines were validated across 4408/1298 (2.5 h/laboratory) detected walking bouts, compared to 4620/1365 bouts detected by a multi-sensor reference system. In the laboratory, the mean absolute error (MAE) and mean relative error (MRE) for walking speed estimation ranged from 0.06 to 0.12 m/s and - 2.1 to 14.4%, with ICCs (Intraclass correlation coefficients) between good (0.79) and excellent (0.91). Real-world MAE ranged from 0.09 to 0.13, MARE from 1.3 to 22.7%, with ICCs indicating moderate (0.57) to good (0.88) agreement. Lower errors were observed for cohorts without major gait impairments, less complex tasks, and longer walking bouts. The analytical pipelines demonstrated moderate to good accuracy in estimating walking speed. Accuracy depended on confounding factors, emphasizing the need for robust technical validation before clinical application.Trial registration: ISRCTN - 12246987.


Asunto(s)
Velocidad al Caminar , Dispositivos Electrónicos Vestibles , Humanos , Anciano , Marcha , Caminata , Proyectos de Investigación
5.
Mov Disord ; 39(2): 328-338, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38151859

RESUMEN

BACKGROUND: Real-world monitoring using wearable sensors has enormous potential for assessing disease severity and symptoms among persons with Parkinson's disease (PD). Many distinct features can be extracted, reflecting multiple mobility domains. However, it is unclear which digital measures are related to PD severity and are sensitive to disease progression. OBJECTIVES: The aim was to identify real-world mobility measures that reflect PD severity and show discriminant ability and sensitivity to disease progression, compared to the Movement Disorder Society-Unified Parkinson's Disease Rating Scale (MDS-UPDRS) scale. METHODS: Multicenter real-world continuous (24/7) digital mobility data from 587 persons with PD and 68 matched healthy controls were collected using an accelerometer adhered to the lower back. Machine learning feature selection and regression algorithms evaluated associations of the digital measures using the MDS-UPDRS (I-III). Binary logistic regression assessed discriminatory value using controls, and longitudinal observational data from a subgroup (n = 33) evaluated sensitivity to change over time. RESULTS: Digital measures were only moderately correlated with the MDS-UPDRS (part II-r = 0.60 and parts I and III-r = 0.50). Most associated measures reflected activity quantity and distribution patterns. A model with 14 digital measures accurately distinguished recently diagnosed persons with PD from healthy controls (81.1%, area under the curve: 0.87); digital measures showed larger effect sizes (Cohen's d: [0.19-0.66]), for change over time than any of the MDS-UPDRS parts (Cohen's d: [0.04-0.12]). CONCLUSIONS: Real-world mobility measures are moderately associated with clinical assessments, suggesting that they capture different aspects of motor capacity and function. Digital mobility measures are sensitive to early-stage disease and to disease progression, to a larger degree than conventional clinical assessments, demonstrating their utility, primarily for clinical trials but ultimately also for clinical care. © 2023 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Asunto(s)
Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/complicaciones , Pruebas de Estado Mental y Demencia , Modelos Logísticos , Índice de Severidad de la Enfermedad , Progresión de la Enfermedad
6.
Front Neurol ; 14: 1247532, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37909030

RESUMEN

Introduction: The clinical assessment of mobility, and walking specifically, is still mainly based on functional tests that lack ecological validity. Thanks to inertial measurement units (IMUs), gait analysis is shifting to unsupervised monitoring in naturalistic and unconstrained settings. However, the extraction of clinically relevant gait parameters from IMU data often depends on heuristics-based algorithms that rely on empirically determined thresholds. These were mainly validated on small cohorts in supervised settings. Methods: Here, a deep learning (DL) algorithm was developed and validated for gait event detection in a heterogeneous population of different mobility-limiting disease cohorts and a cohort of healthy adults. Participants wore pressure insoles and IMUs on both feet for 2.5 h in their habitual environment. The raw accelerometer and gyroscope data from both feet were used as input to a deep convolutional neural network, while reference timings for gait events were based on the combined IMU and pressure insoles data. Results and discussion: The results showed a high-detection performance for initial contacts (ICs) (recall: 98%, precision: 96%) and final contacts (FCs) (recall: 99%, precision: 94%) and a maximum median time error of -0.02 s for ICs and 0.03 s for FCs. Subsequently derived temporal gait parameters were in good agreement with a pressure insoles-based reference with a maximum mean difference of 0.07, -0.07, and <0.01 s for stance, swing, and stride time, respectively. Thus, the DL algorithm is considered successful in detecting gait events in ecologically valid environments across different mobility-limiting diseases.

7.
ERJ Open Res ; 9(5)2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37753279

RESUMEN

Background: Gait characteristics are important risk factors for falls, hospitalisations and mortality in older adults, but the impact of COPD on gait performance remains unclear. We aimed to identify differences in gait characteristics between adults with COPD and healthy age-matched controls during 1) laboratory tests that included complex movements and obstacles, 2) simulated daily-life activities (supervised) and 3) free-living daily-life activities (unsupervised). Methods: This case-control study used a multi-sensor wearable system (INDIP) to obtain seven gait characteristics for each walking bout performed by adults with mild-to-severe COPD (n=17; forced expiratory volume in 1 s 57±19% predicted) and controls (n=20) during laboratory tests, and during simulated and free-living daily-life activities. Gait characteristics were compared between adults with COPD and healthy controls for all walking bouts combined, and for shorter (≤30 s) and longer (>30 s) walking bouts separately. Results: Slower walking speed (-11 cm·s-1, 95% CI: -20 to -3) and lower cadence (-6.6 steps·min-1, 95% CI: -12.3 to -0.9) were recorded in adults with COPD compared to healthy controls during longer (>30 s) free-living walking bouts, but not during shorter (≤30 s) walking bouts in either laboratory or free-living settings. Double support duration and gait variability measures were generally comparable between the two groups. Conclusion: Gait impairment of adults with mild-to-severe COPD mainly manifests during relatively long walking bouts (>30 s) in free-living conditions. Future research should determine the underlying mechanism(s) of this impairment to facilitate the development of interventions that can improve free-living gait performance in adults with COPD.

8.
Sensors (Basel) ; 23(14)2023 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-37514857

RESUMEN

Hereditary spastic paraplegia (HSP) is characterised by progressive lower-limb spasticity and weakness resulting in ambulation difficulties. During clinical practice, walking is observed and/or assessed by timed 10-metre walk tests; time, feasibility, and methodological reliability are barriers to detailed characterisation of patients' walking abilities when instrumenting this test. Wearable sensors have the potential to overcome such drawbacks once a validated approach is available for patients with HSP. Therefore, while limiting patients' and assessors' burdens, this study aims to validate the adoption of a single lower-back wearable inertial sensor approach for step detection in HSP patients; this is the first essential algorithmic step in quantifying most gait temporal metrics. After filtering the 3D acceleration signal based on its smoothness and enhancing the step-related peaks, initial contacts (ICs) were identified as positive zero-crossings of the processed signal. The proposed approach was validated on thirteen individuals with HSP while they performed three 10-metre tests and wore pressure insoles used as a gold standard. Overall, the single-sensor approach detected 794 ICs (87% correctly identified) with high accuracy (median absolute errors (mae): 0.05 s) and excellent reliability (ICC = 1.00). Although about 12% of the ICs were missed and the use of walking aids introduced extra ICs, a minor impact was observed on the step time quantifications (mae 0.03 s (5.1%), ICC = 0.89); the use of walking aids caused no significant differences in the average step time quantifications. Therefore, the proposed single-sensor approach provides a reliable methodology for step identification in HSP, augmenting the gait information that can be accurately and objectively extracted from patients with HSP during their clinical assessment.


Asunto(s)
Trastornos Neurológicos de la Marcha , Paraplejía Espástica Hereditaria , Humanos , Paraplejía Espástica Hereditaria/diagnóstico , Reproducibilidad de los Resultados , Marcha , Caminata , Trastornos Neurológicos de la Marcha/diagnóstico
9.
J Neuroeng Rehabil ; 20(1): 78, 2023 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-37316858

RESUMEN

BACKGROUND: Although digital mobility outcomes (DMOs) can be readily calculated from real-world data collected with wearable devices and ad-hoc algorithms, technical validation is still required. The aim of this paper is to comparatively assess and validate DMOs estimated using real-world gait data from six different cohorts, focusing on gait sequence detection, foot initial contact detection (ICD), cadence (CAD) and stride length (SL) estimates. METHODS: Twenty healthy older adults, 20 people with Parkinson's disease, 20 with multiple sclerosis, 19 with proximal femoral fracture, 17 with chronic obstructive pulmonary disease and 12 with congestive heart failure were monitored for 2.5 h in the real-world, using a single wearable device worn on the lower back. A reference system combining inertial modules with distance sensors and pressure insoles was used for comparison of DMOs from the single wearable device. We assessed and validated three algorithms for gait sequence detection, four for ICD, three for CAD and four for SL by concurrently comparing their performances (e.g., accuracy, specificity, sensitivity, absolute and relative errors). Additionally, the effects of walking bout (WB) speed and duration on algorithm performance were investigated. RESULTS: We identified two cohort-specific top performing algorithms for gait sequence detection and CAD, and a single best for ICD and SL. Best gait sequence detection algorithms showed good performances (sensitivity > 0.73, positive predictive values > 0.75, specificity > 0.95, accuracy > 0.94). ICD and CAD algorithms presented excellent results, with sensitivity > 0.79, positive predictive values > 0.89 and relative errors < 11% for ICD and < 8.5% for CAD. The best identified SL algorithm showed lower performances than other DMOs (absolute error < 0.21 m). Lower performances across all DMOs were found for the cohort with most severe gait impairments (proximal femoral fracture). Algorithms' performances were lower for short walking bouts; slower gait speeds (< 0.5 m/s) resulted in reduced performance of the CAD and SL algorithms. CONCLUSIONS: Overall, the identified algorithms enabled a robust estimation of key DMOs. Our findings showed that the choice of algorithm for estimation of gait sequence detection and CAD should be cohort-specific (e.g., slow walkers and with gait impairments). Short walking bout length and slow walking speed worsened algorithms' performances. Trial registration ISRCTN - 12246987.


Asunto(s)
Tecnología Digital , Fracturas Femorales Proximales , Humanos , Anciano , Marcha , Caminata , Velocidad al Caminar , Modalidades de Fisioterapia
10.
J R Soc Interface ; 20(203): 20230052, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37376872

RESUMEN

The human foot sole is the primary interface with the external world during balance and walking, and also provides important tactile information on the state of contact. However, prior studies on plantar pressure have focused mostly on summary metrics such as overall force or centre of pressure under limited conditions. Here, we recorded spatio-temporal plantar pressure patterns with high spatial resolution while participants completed a wide range of daily activities, including balancing, locomotion and jumping tasks. Contact area differed across task categories, but was only moderately correlated with the overall force experienced by the foot sole. The centre of pressure was often located outside the contact area or in locations experiencing relatively low pressure, and therefore a result of disparate contact regions spread widely across the foot. Non-negative matrix factorization revealed low-dimensional spatial complexity that increased during interaction with unstable surfaces. Additionally, pressure patterns at the heel and metatarsals decomposed into separately located and robustly identifiable components, jointly capturing most variance in the signal. These results suggest optimal sensor placements to capture task-relevant spatial information and provide insight into how pressure varies spatially on the foot sole during a wide variety of natural behaviours.


Asunto(s)
Marcha , Caminata , Humanos , Presión , Pie , Tacto , Fenómenos Biomecánicos
11.
Mov Disord ; 38(8): 1493-1502, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37246815

RESUMEN

BACKGROUND: Rescue of mitochondrial function is a promising neuroprotective strategy for Parkinson's disease (PD). Ursodeoxycholic acid (UDCA) has shown considerable promise as a mitochondrial rescue agent across a range of preclinical in vitro and in vivo models of PD. OBJECTIVES: To investigate the safety and tolerability of high-dose UDCA in PD and determine midbrain target engagement. METHODS: The UP (UDCA in PD) study was a phase II, randomized, double-blind, placebo-controlled trial of UDCA (30 mg/kg daily, 2:1 randomization UDCA vs. placebo) in 30 participants with PD for 48 weeks. The primary outcome was safety and tolerability. Secondary outcomes included 31-phosphorus magnetic resonance spectroscopy (31 P-MRS) to explore target engagement of UDCA in PD midbrain and assessment of motor progression, applying both the Movement Disorder Society Unified Parkinson's Disease Rating Scale Part III (MDS-UPDRS-III) and objective, motion sensor-based quantification of gait impairment. RESULTS: UDCA was safe and well tolerated, and only mild transient gastrointestinal adverse events were more frequent in the UDCA treatment group. Midbrain 31 P-MRS demonstrated an increase in both Gibbs free energy and inorganic phosphate levels in the UDCA treatment group compared to placebo, reflecting improved ATP hydrolysis. Sensor-based gait analysis indicated a possible improvement of cadence (steps per minute) and other gait parameters in the UDCA group compared to placebo. In contrast, subjective assessment applying the MDS-UPDRS-III failed to detect a difference between treatment groups. CONCLUSIONS: High-dose UDCA is safe and well tolerated in early PD. Larger trials are needed to further evaluate the disease-modifying effect of UDCA in PD. © 2023 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Asunto(s)
Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/complicaciones , Ácido Ursodesoxicólico/uso terapéutico , Método Doble Ciego
12.
Front Bioeng Biotechnol ; 11: 1143248, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37214281

RESUMEN

Introduction: Accurately assessing people's gait, especially in real-world conditions and in case of impaired mobility, is still a challenge due to intrinsic and extrinsic factors resulting in gait complexity. To improve the estimation of gait-related digital mobility outcomes (DMOs) in real-world scenarios, this study presents a wearable multi-sensor system (INDIP), integrating complementary sensing approaches (two plantar pressure insoles, three inertial units and two distance sensors). Methods: The INDIP technical validity was assessed against stereophotogrammetry during a laboratory experimental protocol comprising structured tests (including continuous curvilinear and rectilinear walking and steps) and a simulation of daily-life activities (including intermittent gait and short walking bouts). To evaluate its performance on various gait patterns, data were collected on 128 participants from seven cohorts: healthy young and older adults, patients with Parkinson's disease, multiple sclerosis, chronic obstructive pulmonary disease, congestive heart failure, and proximal femur fracture. Moreover, INDIP usability was evaluated by recording 2.5-h of real-world unsupervised activity. Results and discussion: Excellent absolute agreement (ICC >0.95) and very limited mean absolute errors were observed for all cohorts and digital mobility outcomes (cadence ≤0.61 steps/min, stride length ≤0.02 m, walking speed ≤0.02 m/s) in the structured tests. Larger, but limited, errors were observed during the daily-life simulation (cadence 2.72-4.87 steps/min, stride length 0.04-0.06 m, walking speed 0.03-0.05 m/s). Neither major technical nor usability issues were declared during the 2.5-h acquisitions. Therefore, the INDIP system can be considered a valid and feasible solution to collect reference data for analyzing gait in real-world conditions.

13.
Ann Indian Acad Neurol ; 26(Suppl 1): S10-S14, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37092017

RESUMEN

Background: Remote ischemic conditioning (RIC), exposure of body parts to brief periods of circulatory occlusion and reperfusion, has been shown to improve cardiovascular responses to exercise in healthy individuals but its effects in people with MS are unknown. Objective: This study aimed to assess the effect of RIC on heart rate responses to walking in people with MS. Design: Double blind randomized controlled trial. Setting: Multiple sclerosis clinic of tertiary care center teaching hospital in the United Kingdom. Methods: Three cycles of RIC were delivered by occluding the upper arm with a blood pressure cuff inflated to a pressure of 30 mmHg above the systolic blood pressure. In the sham group, the blood pressure cuff was inflated to 30 mmHg below diastolic blood pressure. Heart rate responses to the 6-minute walk test (6MWT), the tolerability of RIC using a numerical rating scale for discomfort (0-10), and adverse events were studied. Results: Seventy-five participants (RIC -38 and Sham-37) completed the study. RIC was well tolerated. Compared to sham, RIC significantly decreased the rise in heart rate (P = 0.04) and percentage of predicted maximum heart rate (P = 0.016) after the 6MWT. Conclusion: RIC was well tolerated and improved the heart rate response to walking in people with MS. Further studies on RIC in the management of MS are needed.

14.
Med Biol Eng Comput ; 61(9): 2341-2352, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37069465

RESUMEN

Walking activity and gait parameters are considered among the most relevant mobility-related parameters. Currently, gait assessments have been mainly analyzed in laboratory or hospital settings, which only partially reflect usual performance (i.e., real world behavior). In this study, we aim to validate a robust walking detection algorithm using a single foot-worn inertial measurement unit (IMU) in real-life settings. We used a challenging dataset including 18 individuals performing free-living activities. A multi-sensor wearable system including pressure insoles, multiple IMUs, and infrared distance sensors (INDIP) was used as reference. Accurate walking detection was obtained, with sensitivity and specificity of 98 and 91% respectively. As robust walking detection is needed for ambulatory monitoring to complete the processing pipeline from raw recorded data to walking/mobility outcomes, a validated algorithm would pave the way for assessing patient performance and gait quality in real-world conditions.


Asunto(s)
Marcha , Caminata , Humanos , Pie , Monitoreo Ambulatorio , Algoritmos
15.
PLoS One ; 18(3): e0273446, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36897869

RESUMEN

Muscle segmentation is a process relied upon to gather medical image-based muscle characterisation, useful in directly assessing muscle volume and geometry, that can be used as inputs to musculoskeletal modelling pipelines. Manual or semi-automatic techniques are typically employed to segment the muscles and quantify their properties, but they require significant manual labour and incur operator repeatability issues. In this study an automatic process is presented, aiming to segment all lower limb muscles from Magnetic Resonance (MR) imaging data simultaneously using three-dimensional (3D) deformable image registration (single inputs or multi-atlas). Twenty-three of the major lower limb skeletal muscles were segmented from five subjects, with an average Dice similarity coefficient of 0.72, and average absolute relative volume error (RVE) of 12.7% (average relative volume error of -2.2%) considering the optimal subject combinations. The multi-atlas approach showed slightly better accuracy (average DSC: 0.73; average RVE: 1.67%). Segmented MR imaging datasets of the lower limb are not widely available in the literature, limiting the potential of new, probabilistic methods such as deep learning to be used in the context of muscle segmentation. In this work, Non-linear deformable image registration is used to generate 69 manually checked, segmented, 3D, artificial datasets, allowing access for future studies to use these new methods, with a large amount of reliable reference data.


Asunto(s)
Imagen por Resonancia Magnética , Músculos , Humanos , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos
16.
Digit Health ; 9: 20552076221150745, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36756644

RESUMEN

Background: This study aimed to explore the acceptability of a wearable device for remotely measuring mobility in the Mobilise-D technical validation study (TVS), and to explore the acceptability of using digital tools to monitor health. Methods: Participants (N = 106) in the TVS wore a waist-worn device (McRoberts Dynaport MM + ) for one week. Following this, acceptability of the device was measured using two questionnaires: The Comfort Rating Scale (CRS) and a previously validated questionnaire. A subset of participants (n = 36) also completed semi-structured interviews to further determine device acceptability and to explore their opinions of the use of digital tools to monitor their health. Questionnaire results were analysed descriptively and interviews using a content analysis. Results: The device was considered both comfortable (median CRS (IQR; min-max) = 0.0 (0.0; 0-20) on a scale from 0-20 where lower scores signify better comfort) and acceptable (5.0 (0.5; 3.0-5.0) on a scale from 1-5 where higher scores signify better acceptability). Interviews showed it was easy to use, did not interfere with daily activities, and was comfortable. The following themes emerged from participants' as being important to digital technology: altered expectations for themselves, the use of technology, trust, and communication with healthcare professionals. Conclusions: Digital tools may bridge existing communication gaps between patients and clinicians and participants are open to this. This work indicates that waist-worn devices are supported, but further work with patient advisors should be undertaken to understand some of the key issues highlighted. This will form part of the ongoing work of the Mobilise-D consortium.

17.
Sci Data ; 10(1): 38, 2023 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-36658136

RESUMEN

Wearable devices are used in movement analysis and physical activity research to extract clinically relevant information about an individual's mobility. Still, heterogeneity in protocols, sensor characteristics, data formats, and gold standards represent a barrier for data sharing, reproducibility, and external validation. In this study, we aim at providing an example of how movement data (from the real-world and the laboratory) recorded from different wearables and gold standard technologies can be organized, integrated, and stored. We leveraged on our experience from a large multi-centric study (Mobilise-D) to provide guidelines that can prove useful to access, understand, and re-use the data that will be made available from the study. These guidelines highlight the encountered challenges and the adopted solutions with the final aim of supporting standardization and integration of data in other studies and, in turn, to increase and facilitate comparison of data recorded in the scientific community. We also provide samples of standardized data, so that both the structure of the data and the procedure can be easily understood and reproduced.

18.
J Neuroeng Rehabil ; 19(1): 141, 2022 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-36522646

RESUMEN

BACKGROUND: Measuring mobility in daily life entails dealing with confounding factors arising from multiple sources, including pathological characteristics, patient specific walking strategies, environment/context, and purpose of the task. The primary aim of this study is to propose and validate a protocol for simulating real-world gait accounting for all these factors within a single set of observations, while ensuring minimisation of participant burden and safety. METHODS: The protocol included eight motor tasks at varying speed, incline/steps, surface, path shape, cognitive demand, and included postures that may abruptly alter the participants' strategy of walking. It was deployed in a convenience sample of 108 participants recruited from six cohorts that included older healthy adults (HA) and participants with potentially altered mobility due to Parkinson's disease (PD), multiple sclerosis (MS), proximal femoral fracture (PFF), chronic obstructive pulmonary disease (COPD) or congestive heart failure (CHF). A novelty introduced in the protocol was the tiered approach to increase difficulty both within the same task (e.g., by allowing use of aids or armrests) and across tasks. RESULTS: The protocol proved to be safe and feasible (all participants could complete it and no adverse events were recorded) and the addition of the more complex tasks allowed a much greater spread in walking speeds to be achieved compared to standard straight walking trials. Furthermore, it allowed a representation of a variety of daily life relevant mobility aspects and can therefore be used for the validation of monitoring devices used in real life. CONCLUSIONS: The protocol allowed for measuring gait in a variety of pathological conditions suggests that it can also be used to detect changes in gait due to, for example, the onset or progression of a disease, or due to therapy. TRIAL REGISTRATION: ISRCTN-12246987.


Asunto(s)
Marcha , Enfermedad de Parkinson , Adulto , Humanos , Caminata , Velocidad al Caminar , Proyectos de Investigación
19.
Front Med (Lausanne) ; 9: 996903, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36213641

RESUMEN

The loss of mobility is a common trait in multiple health conditions (e.g., Parkinson's disease) and is associated with reduced quality of life. In this context, being able to monitor mobility in the real world, is important. Until recently, the technology was not mature enough for this; but today, miniaturized sensors and novel algorithms promise to monitor mobility accurately and continuously in the real world, also in pathological populations. However, before any such methodology can be employed to support the development and testing of new drugs in clinical trials, they need to be qualified by the competent regulatory agencies (e.g., European Medicines Agency). Nonetheless, to date, only very narrow scoped requests for regulatory qualification were successful. In this work, the Mobilise-D Consortium shares its positive experience with the European regulator, summarizing the two requests for Qualification Advice for the Mobilise-D methodologies submitted in October 2019 and June 2020, as well as the feedback received, which resulted in two Letters of Support publicly available for consultation on the website of the European Medicines Agency. Leveraging on this experience, we hereby propose a refined qualification strategy for the use of digital mobility outcome (DMO) measures as monitoring biomarkers for mobility in drug trials.

20.
PLoS One ; 17(10): e0269615, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36201476

RESUMEN

BACKGROUND: The development of optimal strategies to treat impaired mobility related to ageing and chronic disease requires better ways to detect and measure it. Digital health technology, including body worn sensors, has the potential to directly and accurately capture real-world mobility. Mobilise-D consists of 34 partners from 13 countries who are working together to jointly develop and implement a digital mobility assessment solution to demonstrate that real-world digital mobility outcomes have the potential to provide a better, safer, and quicker way to assess, monitor, and predict the efficacy of new interventions on impaired mobility. The overarching objective of the study is to establish the clinical validity of digital outcomes in patient populations impacted by mobility challenges, and to support engagement with regulatory and health technology agencies towards acceptance of digital mobility assessment in regulatory and health technology assessment decisions. METHODS/DESIGN: The Mobilise-D clinical validation study is a longitudinal observational cohort study that will recruit 2400 participants from four clinical cohorts. The populations of the Innovative Medicine Initiative-Joint Undertaking represent neurodegenerative conditions (Parkinson's Disease), respiratory disease (Chronic Obstructive Pulmonary Disease), neuro-inflammatory disorder (Multiple Sclerosis), fall-related injuries, osteoporosis, sarcopenia, and frailty (Proximal Femoral Fracture). In total, 17 clinical sites in ten countries will recruit participants who will be evaluated every six months over a period of two years. A wide range of core and cohort specific outcome measures will be collected, spanning patient-reported, observer-reported, and clinician-reported outcomes as well as performance-based outcomes (physical measures and cognitive/mental measures). Daily-living mobility and physical capacity will be assessed directly using a wearable device. These four clinical cohorts were chosen to obtain generalizable clinical findings, including diverse clinical, cultural, geographical, and age representation. The disease cohorts include a broad and heterogeneous range of subject characteristics with varying chronic care needs, and represent different trajectories of mobility disability. DISCUSSION: The results of Mobilise-D will provide longitudinal data on the use of digital mobility outcomes to identify, stratify, and monitor disability. This will support the development of widespread, cost-effective access to optimal clinical mobility management through personalised healthcare. Further, Mobilise-D will provide evidence-based, direct measures which can be endorsed by regulatory agencies and health technology assessment bodies to quantify the impact of disease-modifying interventions on mobility. TRIAL REGISTRATION: ISRCTN12051706.


Asunto(s)
Fragilidad , Enfermedad de Parkinson , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Monitoreo Fisiológico , Estudios Observacionales como Asunto , Modalidades de Fisioterapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...